Publications

Relationship between the use of new or used computed tomography scanners and image retake rates in South Korea

Full metadata record

DC Field Value
dc.contributor.authorJae-Seok Hong
dc.contributor.authorKang, Hee-Chung
dc.date.accessioned2017-01-25T04:10:08Z
dc.date.available2017-01-25T04:10:08Z
dc.date.issued2013-04-30
dc.identifier.issn0284-1851
dc.identifier.urihttps://repository.kihasa.re.kr/handle/201002/25066
dc.description.abstractBackground The use of high-cost imaging has increased worldwide, contributing to increased healthcare expenditures. Without proper quality verification, the installation of used imaging equipment may lead to wasteful increases in cost due to ineffective and poor-quality imaging that requires repeat scans. Purpose To examine the relationship between the use of new or used computed tomography (CT) scanners and image retake rates to evaluate the comparative quality of used and new CT scanners. Material and Methods This was a retrospective cohort study of patients who first underwent CT from January 1 to June 30, 2008 (n = 258,572). Data were obtained by linking the Health Care Institution Registration Data with the Korean National Health Insurance Claims Database. Image retake rates within 30, 60, 90, and 180 days after the first CT scan were calculated, and differences in the image retake rate by new versus used CT scanners were assessed. Results After adjusting for confounders, use of a used CT scanner for the first scan increased the odds of retake within 30 days (odds ratio [OR]: 1.34, 95% confidence interval [CI]: 1.22–1.48), 60 days (OR: 1.59, 95% CI: 1.47–1.72), 90 days (OR: 1.48, 95% CI: 1.38–1.59), and 180 days (OR: 1.38, 95% CI: 1.30–1.46) compared with use of a new CT scanner. Such results were evident in scans of the spine, abdomen, chest, and face or skull base. Conclusion The quality control associated with import of used CT scanners should be improved. Moreover, regular and detailed quality inspections of used CT scanners currently operating in healthcare institutions are necessary.
dc.format.extent7
dc.languageeng
dc.publisherRoyal Society of Medicine Press
dc.titleRelationship between the use of new or used computed tomography scanners and image retake rates in South Korea
dc.typeArticle
dc.type.localArticle(Academic)
dc.identifier.apprname학술논문평가
dc.subject.keywordComputed tomography scanner
dc.subject.keywordmedical devices
dc.subject.keywordquality of healthcare
dc.contributor.affiliatedAuthor강희정
dc.citation.titleActa radiologica
dc.citation.volume54
dc.citation.number4
dc.citation.startPage428
dc.citation.endPage434
dc.identifier.bibliographicCitationActa radiologica, vol. 54, no. 4, pp. 428 - 434